Copley Controls Serial Encoder Guida Utente Pagina 111

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 180
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 110
Xenus XTL User Guide Quick Setup with CME 2
Copley Controls Corp. 103
5.8.2: Auto Phase Procedure
NOTE: The following steps use a brushless rotary motor. Screens and sequences vary by motor type.
5.8.2.1 Verify that the Enable Input is not activated.
5.8.2.2 Apply HV or AC power.
Click Auto Phase to open the Auto Phase Motor Direction Setup screen.
5.8.2.3 Move the motor in the direction to be considered positive
OR if you cannot move the motor, click Skip (you will confirm motor direction later).
NOTE: If an output is configured as a brake you can temporarily release the brake by
holding down the Release Brake button. The brake will be reactivated when you release
the button..
The Actual Position value on the screen should change. If it does not change, see Trouble
Shoot Motor Direction Setup (p. 107).
5.8.2.4 Click Next to display the Auto Phase Motor Wiring Setup screen.
Vedere la pagina 110
1 2 ... 106 107 108 109 110 111 112 113 114 115 116 ... 179 180

Commenti su questo manuale