Copley Controls Serial Encoder Guida Utente Pagina 143

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 157
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 142
Xenus Plus User Guide Xenus Plus Filter
Copley Controls 143
D.5: XTL-FA-01 Edge Filter Wiring
This section describes the wiring of the XTL-FA-01 Edge Filter.
D.5.1: Electrical Codes and Warnings
Be sure that all wiring complies with the National Electrical Code (NEC) or its national equivalent,
and all prevailing local codes.
DANGER
DANGER: Hazardous voltages.
Exercise caution when installing.
Failure to heed this warning can cause equipment damage, injury, or death.
DANGER
Risk of electric shock.
High-voltage circuits on Xenus Plus J1, J2, and J3 and on Filter J1 and J2 are
connected to mains power.
Failure to heed this warning can cause equipment damage, injury, or death.
WARNING
Do not ground mains-connected circuits.
With the exception of the ground pins on Xenus Plus J1, J2, and J3 and on Filter J1
and J2, all of the other circuits on these connectors are mains-connected and must
never be grounded.
Failure to heed this warning can cause equipment damage.
!
!
!
Vedere la pagina 142
1 2 ... 138 139 140 141 142 143 144 145 146 147 148 ... 156 157

Commenti su questo manuale

Nessun commento