CME 2 User Guide Motor Phasing
Copley Controls 105
...Manual Phase Example: Motor with Encoder, continued:
7
Verify actual position count agrees with direction of rotation: increasing counts in
forward direction and decreasing counts in reverse direction. If it does not, toggle the
Motor Feedback Invert Input box setting.
8
If the motor has no Halls, skip to Phase Initialization Steps for Motor without Halls (p.
106).
9
Monitor the vector rotation through one electrical cycle for proper Hall transitions:
Verify that the red indicator rotates in the same direction as the motor phase angle,
and that the transition occurs when the needle is between indicators (±30 degrees,
as shown below).
If the needle and Hall states do not track properly, use the Hall Wiring list box and/or
Invert Input options (shown below) to swap the amplifier’s Hall wire configuration.
If the red indicator transition leads or lags behind the centered needle by more than
30 degrees, then try adjusting the Hall Offset in +/- 30 degree increments:
10
Phasing of a motor with encoder and Halls is complete. Click OK.