CME 2 User Guide Stepper Controls
Copley Controls 141
Click the Position Loop Values tab:
Change/verify the values as needed:
The level (in encoder counts) at which the following error produces a fault,
which stops the servo loop. We recommend raising the fault level before
tuning the loop. See Following Error Fault Details (p. 91).
The level (in counts) at which the following error produces a warning (without
stopping the loop). See Following Error Fault Details (p. 91).
Stops following error from faulting. See Following Error Fault Details (p. 91).
Width of tracking window in counts. See Tracking Window Details (p. 92).
Position must remain in the tracking window for this amount of time to be
considered tracking. See Tracking Window Details (p. 92).
Click Close to close the window.
On the CME 2 Main screen, click Save to Flash.