Motor Phasing CME 2 User Guide
96 Copley Controls
…Auto Phase Example, continued:
9
When you are ready to observe motion, click OK. See the prompt:
10
If motor did not turn 1 full turn, click No and see Phase count test problems (p. 103).
If motor turned 1 full turn, click Yes.
The message area displays progress and completion messages.
11
For a resolver (R) version of a Copley Controls amplifier, skip to Step 13 (p. 97).
For a non-resolver amplifier, click Next to open the Hall Wiring Setup screen.
12
Click Start to begin the Halls wiring setup. The message area displays the messages:
Microstepping. Test Complete. Motor has been properly phased.
During microstepping, a current vector is applied to the motor windings and
microstepped through an electrical cycle at a set rate, causing the motor to move. As
the motor moves the Hall lines are decoded for proper commutation.
If the step fails, see Halls wiring setup problems (p. 103).