CME 2 User Guide Motor Phasing
Copley Controls 107
10.4.2: Manual Phase Example: Motor with Resolver
Make sure that no load is connected to the motor.
On the Main screen, choose ToolsManual Phase to open the window:
Verify the Current setting and then enable the amp by selecting Enable in the Control
area of the Manual Phase window.
To control the current vector rotation, command the motor forward or reverse.
NOTE: Some motors have bearings stiction, so helping the motor with mechanical
force is acceptable. Motors with no friction may need friction added to steady motion.
If the motor cannot keep up with the rate of vector rotation, then reduce the Increment
Rate or increase the Current.
Verify that pressing forward button moves motor forward. If it does not, toggle the
Motor Invert Output box setting.
Verify actual position count agrees with direction of rotation: increasing counts in
forward direction and decreasing counts in reverse direction. If it does not, toggle the
Motor Feedback Invert Input box setting.
Commenti su questo manuale