Parameter Dictionary Parameters
2.1: Parameters Sorted by ASCII Interface Parameter ID
Current Loop Proportional Gain (Cp).
Current Loop Integral Gain (Ci).
Current loop programmed value. This current will be used to command the drive
when Desired State (0x24) is set to 1. Units: 0.01 A.
Winding A Current. Actual current measured at winding A. Units: 0.01 A.
Winding B Current. Actual current measured at winding B. Units: 0.01 A.
Current Offset A. Offset value applied to the winding A current reading. This offset is
calculated by the drive at startup. Units: 0.01 A.
Current Offset B. Offset value applied to the winding B current reading. This offset is
calculated by the drive at startup. Units: 0.01 A.
X axis of calculated stator current vector. Units: 0.01 A.
Y axis of calculated stator current vector. Units: 0.01 A.
Current loop output, X axis of stator space.
Current loop output, Y axis of stator space.
Actual Current, D axis of rotor space. Units: 0.01 A.
0x0C 0x0D 0x40C 0x2215 R* INT16 Actual Current, Q axis of rotor space. Units: 0.01 A.
Commanded current, D axis of rotor space. Part of the internal current loop
calculation. Units: 0.01 A.
Commanded Current, Q axis of rotor space. Part of the internal current loop
calculation. Units: 0.01 A.
Current Error, D axis of rotor space. Units: 0.01 A.
Current Error, Q axis of rotor space. Units: 0.01 A.
Current Integral Value, D axis of rotor space.
0x12 0x13 0x412 None R* INT16 Current Integral Value, Q axis of rotor space.
Current Loop Output, D axis of rotor space.
Current Loop Output, Q axis of rotor space.