Parameter Dictionary Parameters
words
Second chained biquad filter on output of velocity loop, see Filter Coefficients (p. 73).
words
Third chained biquad filter on output of velocity loop. 14 word parameter, see Filter
Coefficients (p. 73).
words
First chained biquad filter on input of current loop. 14 word parameter, see Filter
Coefficients (p. 73).
words
Second chained biquad filter on input of current loop. 14 word parameter, see Filter
Coefficients (p. 73).
Servo loop configuration. This parameter allows various parts of the drive servo
loops to be enabled/disabled. Bit-mapped as follows:
If set, this disables the velocity loop gains. The velocity loop command feed forward gain
(parameter 0x157) is still active as are the velocity loop output filters.
If set, this enables the position loop I and D gains (parameters 0x155 and 0x156). If clear,
these parameters are treated as zeros.
Position loop integral gain (KI).
Derivative gain for position loop (KD).
Velocity loop command feed forward. The input command (after limiting) to the
velocity loop is scaled by this value and added in to the output of the velocity loop.
Integral drain for position loop.
Abort option code for CANopen / EtherCAT drives.